Combination Tap Assemblies

Section Code 0450 : Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.

Back To Directory Sections

#1906905

Single hole, single outlet fixed combination tap assembly (Chrome plated brass), incorporating a quarter turn ceramic disk headwork with a single lever operating member. Temperature is controlled independently via a thermostatic cartridge with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum operating pressure - 10.0 bar. Maximum operating temperature - 65°C

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1906905
Expiry date:
30/06/2024
Size:
15mm copper tails
Marking:
Bristan etching on body
Installation Requirements:
R001 R006 R010
Model:
AR2 THLBAS C
Factor:
Bristan Group Ltd.
Company Name
Bristan Group Ltd.
Address
Birch Coppice Business Park, Pooley Hall Drive, Dordon, Tamworth. Staffordshire
Postcode
B78 1SG.
Country
United Kingdom
Phone
0844 7016274

View All Listings by this Company

Print This Approval


#1906906

Range of single hole, single outlet fixed combination tap assemblies (Chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator (WM SLE BASNW3.5 C) or plastic flow straightener (WM RYL BASNW4.5 C) Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1906906
Expiry date:
30/06/2024
Size:
PVC flexible unbraided hose assembly with 15mm push fit end connections
Marking:
Bristan on operating member
Installation Requirements:
R001 R006 R010
Model:
WM SLE BASNW3.5 C, WM RYL BASNW4.5 C,
Factor:
Bristan Group Ltd.
Company Name
Bristan Group Ltd.
Address
Birch Coppice Business Park, Pooley Hall Drive, Dordon, Tamworth. Staffordshire
Postcode
B78 1SG.
Country
United Kingdom
Phone
0844 7016274

View All Listings by this Company

Print This Approval


#1905337

Range of single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905337
Expiry date:
31/05/2024
Size:
Stainless steel braided PEX lined hose assembly incorporating ½” captive nut connections
Marking:
Lota on body
Installation Requirements:
R001 R006 R009 R010
Model:
60128-5001
Manufacturer:
Xiamen Lota International Co. Ltd.
Company Name
Xiamen Lota International Co. Ltd.
Address
No 61 Xingnan Road Jimei District Xiamen 361022
Country
China

View All Listings by this Company

Print This Approval


#1906319

Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure 10.0 bar. The T8102M & T9202 models incorporate a plastic flow straightener and have a maximum operating temperature of 60°C. Models T99002M, T9902, T9902L have a maximum operating temperature of 85°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1906319
Expiry date:
30/06/2024
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating ½” captive nut end connections
Marking:
Xindong logo on operating member
Installation Requirements:
R001 R006 R009 R010
Model:
T8102M, T9902M, T9902, T9902L & T9202
Manufacturer:
Zhejiang Xindong Sanitary Ware Co.,Ltd.
Company Name
Zhejiang Xindong Sanitary Ware Co.,Ltd.
Address
Xuanmen Industrial Zone Yuhuan, Zhejiang
Country
China

View All Listings by this Company

Print This Approval


#1906320

Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1906320
Expiry date:
30/06/2024
Size:
Stainless steel braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections
Marking:
Xindong logo on operating member
Installation Requirements:
R001 R006 R010
Model:
T8102 & T8302
Manufacturer:
Zhejiang Xindong Sanitary Ware Co.,Ltd.
Company Name
Zhejiang Xindong Sanitary Ware Co.,Ltd.
Address
Xuanmen Industrial Zone Yuhuan, Zhejiang
Country
China

View All Listings by this Company

Print This Approval


#1907015

Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a single sequential cartridge that controls both the flow and temperature with a single lever operating member. The spout outlets incorporate a plastic flow straightener. All products are supplied with a plastic strainer and a servicing valve, x2 EPDM ‘O’-rings, brass adaptor, plastic flow regulator and brass flow regulator holder for installation on each inlet tail. The models ending in 610/610L are supplied with copper tails and an additional olive. All other models are supplied with stainless steel braided PEX lined flexible hose assemblies with ⅜” captive nut end connections and an additional fibre washer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1907015
Expiry date:
31/07/2024
Size:
½” BSP (M) (to servicing valve)
Marking:
Delabie on operating member
Installation Requirements:
R001 R006 R009 R010
Model:
Securitherm H9600, H9600610, H9600610L, H960015 & H960015L. Securitherm Bioclip H9605, H9605610, H9605610L, H960515 & H960515L
Factor:
Delabie Ltd.
Company Name
Delabie Ltd.
Address
1-3 Henderson House Hithercroft Road Wallingford
Postcode
OX10 9DG
Country
Oxfordshire
Phone
+44 1491 824 449

View All Listings by this Company
Manufacturer:
Delabie SAS
Company Name
Delabie SAS
Address
18 Rue Du Marechal Foch 80130 Friville Escarbotin France

View All Listings by this Company

Print This Approval


#1907027

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic cartridge headworks with dome type operating member. The spout outlet incorporates a plastic aerator. The product is supplied with an optional plastic flow straightener & pop up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1907027
Expiry date:
31/07/2024
Size:
Stainless steel braided EPDM lined hose assembly incorporating 15mm compression end connections
Marking:
Ideal Standard Logo on operating member
Installation Requirements:
R001 R006 R010
Model:
B9673AA Alto Dual Control Basin Mixer
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1907904

Single hole single outlet fixed combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1907904
Expiry date:
31/07/2024
Size:
Stainless steel braided EPDM lined flexible hose assembly with 15mm compression end connections
Marking:
Bristan on operating member
Installation Requirements:
R001 R006 R010
Model:
RGL CAP BASNW C
Factor:
Bristan Group Limited
Company Name
Bristan Group Limited
Address
Birch Coppice Business Park Pooley Hall Drive Dordon
Postcode
B78 1SG
Country
Tamworth
Phone
01827 254144
General Email
enquire@bristan.com

View All Listings by this Company

Print This Approval


#1907907

Range of single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge or quarter turn ceramic disc headwork with either a single lever or cross top operating member. The spout outlets incorporate a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1907907
Expiry date:
31/07/2024
Size:
Stainless steel braided EPDM lined hose assemblies with ½” BSP female captive nut end connections
Marking:
Cascade on body or operating member
Installation Requirements:
R001 R006 R010
Model:
002.2119.3, 004.2119.3, 005.2119.3, 007.2119.3 & 008.2119.3
Factor:
Bristan Group Ltd.
Company Name
Bristan Group Ltd.
Address
Birch Coppice Business Park, Pooley Hall Drive, Dordon, Tamworth. Staffordshire
Postcode
B78 1SG.
Country
United Kingdom
Phone
0844 7016274

View All Listings by this Company

Print This Approval


#1907909

Single hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1907909
Expiry date:
31/07/2024
Size:
Stainless steel braided EPDM lined flexible hose assembly with 15mm compression end connections
Marking:
Cascade on operating member
Installation Requirements:
R001 R006 R010
Model:
001.2119.3
Factor:
Bristan Group Ltd.
Company Name
Bristan Group Ltd.
Address
Birch Coppice Business Park, Pooley Hall Drive, Dordon, Tamworth. Staffordshire
Postcode
B78 1SG.
Country
United Kingdom
Phone
0844 7016274

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 4 of 57

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.